Dove期刊
期刊
会议
图书
作者:Guy Richards , Riana Cockeran , Helen Steel ...
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.219-224Dove
摘要:Catheter related blood stream infections increase morbidity, mortality and cost. This study investigated whether Certofix Protect® Antimicrobial catheters carry surface charge and whether this inhibits biofilm formation.The capacitance of the catheter surfaces was measured a...
作者:Tengku Hamid , Siti Saadiah Hassan Nudin , Chan Yoke Mun ...
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.225-230Dove
摘要:The current study aimed to show the effects of oral health, diabetes mellitus (DM), hypertension (HT), heart disease, functional status and socio-demographic factors on the risk of falls in the elderly with dementia. Approximately, the prevalence of falls was 17% in subjects. It ...
作者:Meir Nitzan , Robert Koppel , Ayal Romem
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.231-239Dove
摘要:Oxygen saturation in the arterial blood, SaO2, provides information on the adequacy of the respiratory function. SaO2 can be assessed noninvasively by pulse oximetry which is based on photoplethysmographic (PPG) pulses in two wavelengths, generally in the red and infrared regions...
作者:Sachin Shridharani , Justin Broyles , Alan Matarasso
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.241-251Dove
摘要:Since its introduction by Illouz and others over thirty years ago, suction assisted lipectomy/liposuction/lipoplasty has evolved tremendously and has developed into one of the most popular procedures in aesthetic plastic surgery. Liposuction is an effective procedure employe...
作者:Sam Eriksson , Christian Sturesson , Lindell Gert ...
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.257-261Dove
摘要:Background: Liver microcirculation can be affected by a wide variety of causes relevant in liver transplantation and resectional surgery. Intra-operative assessment of the microcirculation can possibly predict postoperative outcome. The present pilot study introduces laser s...
作者:Jeffrey Clymer , Ryan Asher , Alissa Welling ...
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.263-271Dove
摘要:Ultrasonic energy in surgery is a mainstay in the armamentarium of surgeons providing multifunctionality, precision and control when dissecting and sealing vessels up to 5 mm in diameter. The ability to seal vessels in the 5 to 7 mm range has been a limitation of ultrasonic ...
作者:Rajnish Patel , Sunita Ubale
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.253-256Dove
摘要:ABSTRACTBackground: Obstetric Anal Sphincter Injuries (OASIS) are the leading cause of anal incontinence in women. Episiotomies with a post-delivery suture angle of less than 30 degrees to the midline are more likely to injure the anal sphincter directly, while those with a ...
作者:Faisal Khasawneh , Joshua Stewart , Hazem Abugrara ...
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.273-281Dove
摘要:Abstract:Background: It is considered standard practice to use disposable or patient-dedicated stethoscopes to prevent cross contamination between patients in contact precautions and others in their vicinity. The literature offers very little information regarding the qualit...
作者:Wan'an Yang , Chengbing Tang , Fengqing Qin
来源:[J].Medical Devices: Evidence and Research, 2014, Vol.2014 (default), pp.283-289Dove
摘要:To control and drive the robotic capsule accurately from outside the patient’s body, we present a schema that the capsule enclosing the imaging device, circuits, batteries, and so on is looped a ring permanent-magnet which acts as actuator. A cuboidal permanent fixed on a br...

我们正在为您处理中,这可能需要一些时间,请稍等。

资源合作:cnki.scholar@cnki.net, +86-10-82896619   意见反馈:scholar@cnki.net

×