全部文献期刊学位论文会议报纸专利标准年鉴图书|学者科研项目
中外文文献  中文文献  外文文献
作者:Wenchao Su , Liang Qi , Ruizhong Hu ...
来源:[J].Chinese Science Bulletin(IF 1.319), 1998, Vol.43 (22), pp.1922-1927Springer
摘要:Abstract(#br)Inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine rare-earth elements abundances in fluid inclusions. Quartz separates from the Lannigou and Yata Carlin-type gold deposits, southwestern China, were prepared by the decrepitation-leach method. ...
作者:Baoping Li , Jianxin Zhao , Kenneth D. Collerson ...
来源:[J].Chinese Science Bulletin(IF 1.319), 2003, Vol.48 (12), pp.1219-1224Springer
摘要:Abstract(#br)Thirty-nine trace elements of the Song-Yuan period (960–1368 AD) porcelain bodies from Cizhou, Jizhou and Longquanwu kilns were analyzed with ICP-MS, a technique rarely used in Chinese archaeometry, to investigate its potential application in such studies. Trace ...
作者:Yang Zhao , Zhiding Huang , Chao Wei ...
来源:[J].Chromatographia(IF 1.437), 2017, Vol.80 (11), pp.1623-1631Springer
摘要:... This paper reports a novel method where isotope dilution high performance liquid chromatography inductively coupled plasma mass spectrometry (ID-HPLC–ICP-MS) was combined with low temperature extraction for the determination of tributyltin (TBT) in tannery wastewater fro...
作者:Lorenzo Milani , Robert Bolhar , R. Grant Cawthorn ...
来源:[J].Mineralium Deposita(IF 2.147), 2017, Vol.52 (5), pp.747-768Springer
摘要:In situ laser ablation inductively coupled plasma mass spectrometry (LA–ICP-MS) and electron probe microanalysis (EPMA) are used to characterize magnetite and ilmenite of the phoscorite–carbonatite association at Phalaborwa. We trace the behavior of the compatible elements...
作者:Hendryk Gemeiner , Thiago de Araujo Dourado , Everton Tiago Sulato ...
来源:[J].Environmental Science and Pollution Research(IF 2.618), 2017, Vol.24 (25), pp.20616-20625Springer
摘要:The toxic metal lead (Pb) can be harmful to human health in various manners, but is also considered as a distinguished tracer of environmental pollution since the relative abundance of its four stable isotopes with the atomic masses of 204, 206, 207, and 208 varies with the ...
作者:Yan Li , Hua Yu , Siqian Zheng ...
来源:[J].International Journal of Environmental Research and Public Health(IF 1.998), 2016, Vol.13 (3)DOAJ
摘要:... With the aim of exploring a sensitive and reliable indicator of estimating exposure level to REEs, a simple, accurate and specific ICP-MS method for simultaneous direct quantification of 15 REEs (89Y, 139La, 140Ce, 141Pr, 146Nd, 147Sm, 153Eu, 157Gd, 159Tb, 163Dy, 165Ho, 1...
作者:Éder José dos Santos , Amanda Beatriz Herrmann , José Luiz Olkuszewski ...
来源:[J].Brazilian Archives of Biology and Technology(IF 0.473), 2005, Vol.48 (5), pp.681-687DOAJ
摘要:The performance of axial view ICP OES and ICP-MS techniques were compared through the determination of As, Fe, Mn, Pb, Sb and Sn in electrolytic copper. Samples were prepared by two procedures: 1. Total dissolution with 5 % v/v HNO3 and 2. Dissolution with 1.4 % v/v HNO3 plus 2...
作者:Jinsung An , Hosub Lee , Kyoungphile Nam ...
来源:[J].Microchemical Journal(IF 2.879), 2017, Vol.131, pp.170-173Elsevier
摘要:Abstract(#br)In the analysis of arsenic (As) with ICP-MS, it was observed that methanol addition to the sample decreases the amount of 40 Ar 35 Cl + formed in the previous study. To investigate the effect of methanol addition on generation of isobaric polyatomic ions and its mech...
作者:Jinsung An , Hosub Lee , Kyoungphile Nam ...
来源:[J].Microchemical Journal(IF 2.879), 2017, Vol.131, pp.170-173Elsevier
摘要:Abstract(#br)In the analysis of arsenic (As) with ICP-MS, it was observed that methanol addition to the sample decreases the amount of 40 Ar 35 Cl + formed in the previous study. To investigate the effect of methanol addition on generation of isobaric polyatomic ions and its mech...
作者:Juan A.V.A. Barros , Alex Virgilio , Daniela Schiavo ...
来源:[J].Microchemical Journal(IF 2.879), 2017, Vol.133, pp.567-571Elsevier
摘要:... For Mo determinations in plant materials an ICP-MS with tandem configuration (ICP-MS/MS) with an octopole reaction system (ORS 3 ) pressurized with oxygen gas and operating in MS/MS mode was employed to overcome polyatomic interferences caused by K, a major element in plant...

我们正在为您处理中,这可能需要一些时间,请稍等。

资源合作:cnki.scholar@cnki.net, +86-10-82896619   意见反馈:scholar@cnki.net

×