全部文献期刊学位论文会议报纸专利标准年鉴图书|学者科研项目
中外文文献  中文文献  外文文献
作者:David Martínez , Daniel Torregrosa , Guillermo Grindlay ...
来源:[J].Talanta(IF 3.498), 2018, Vol.176, pp.374-381Elsevier
摘要:Abstract(#br)Coupling dispersive liquid-liquid micro-extraction (DLLME) to inductively coupled plasma atomic emission spectrometry (ICP-AES) is usually troublesome due to the limited plasma tolerance to the organic solvents usually employed for metal extraction. This work explor...
作者:I. I. Evdokimov , V. G. Pimenov , D. A. Fadeeva
来源:[J].Journal of Analytical Chemistry(IF 0.616), 2018, Vol.73 (4), pp.334-343Springer
摘要:Abstract(#br)Possibilities of inductively coupled plasma atomic emission spectrometry (ICP AES) as an alternative to X-ray spectrochemical analysis are estimated in the determination of matrix elements of glasses of As–Se and As–S systems. Standard solutions were prepared fr...
作者:Qin-Bao Lin , He Li , Huai-Ning Zhong ...
来源:[J].Analytical Letters(IF 0.965), 2014, Vol.47 (12), pp.2095-2103Taylor & Francis
摘要:Titanium was determined in nano-titanium(IV) oxide food packaging by microwave digestion with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Microwave digestion was optimized using different acid comb...
作者:N. S. Medvedev , A. V. Malitskii , A. R. Tsygankova ...
来源:[J].Journal of Analytical Chemistry(IF 0.616), 2018, Vol.73 (6), pp.533-538Springer
摘要:Abstract(#br)The introduction of various forms of molybdenum into an inductively coupled plasma was studied in the vaporization of solutions from a graphite tube. A temperature program is selected that enables the separated vaporization of analytes and molybdenum (matrix) for atomic emission spectrometry...
作者:Guillermo Grindlay , Luis Gras , Juan Mora ...
来源:[J].Spectrochimica Acta Part B: Atomic Spectroscopy(IF 3.141), 2016, Vol.115, pp.8-15Elsevier
摘要:Abstract(#br)In this work, the influence of carbon-, sulfur-, and phosphorus-based charge transfer reactions on the emission signal of 34 elements (Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Ga, Hg, I, In, Ir, K, Li, Mg, Mn, Na, Ni, P, Pb, Pd, Pt, S, Sb, Se, Sr, Te, and ...
作者:Sang-Deuk Kim , Jae-Min Lim , Won Lee ...
来源:[J].Microchemical Journal(IF 2.879), 2004, Vol.78 (2), pp.127-134Elsevier
摘要:Abstract(#br)A novel method for the determination of trace elements in microliter samples using the tantalum filament electrothermal vaporization/low-pressure inductively coupled plasma (ETV/LP-ICP) atomic emission spectrometry has been developed. An improved tantalum filament...
作者:I.I. Evdokimov , D.А. Fadeeva , V.G. Pimenov
来源:[J].Journal of Non-Crystalline Solids(IF 1.597), 2018, Vol.480, pp.34-37Elsevier
摘要:Abstract(#br)It is demonstrated that inductively coupled atomic emission spectrometry (ICP-AES) can be successfully used for determination of matrix elements of As–S glasses with the expanded uncertainty within 0.05–0.1 mol%. The main advantage of ICP-AES method as compared ...
作者:Amanda C. Davis , Clifton P. Calloway , Bradley T. Jones
来源:[J].Microchemical Journal(IF 2.879), 2006, Vol.84 (1), pp.31-37Elsevier
摘要:... The extracts are analyzed by inductively coupled plasma atomic emission spectrometry using a tungsten-coil as an electrothermal vaporizer. A 20-μl aliquot of the extract is injected directly onto the coil. Two Cd atomic emission lines are observed simultaneously: 228.8 nm ...
作者:María Rosende , Luis M. Magalhães , Marcela A. Segundo ...
来源:[J].Analytica Chimica Acta(IF 4.387), 2014, Vol.842, pp.1-10Elsevier
摘要:... A unified bioaccessibility/BARGE method (UBM)-like physiological-based extraction test is evaluated for the first time in a dynamic format for accurate assessment of in-vitro bioaccessibility of Cr, Cu, Ni, Pb and Zn in forest and residential-garden soils by on-line coupling of a hybrid flow set-up to inductively coupled plasma atomic emission spectrometry...
作者:J.G. Choi , H.Y. Kim , H.B. Lim
来源:[J].Microchemical Journal(IF 2.879), 1999, Vol.63 (1), pp.119-127Elsevier
摘要:Abstract(#br)Two kinds of ferrite powder were analyzed by inductively coupled plasma atomic emission spectrometry. High-grade Fe 2 O 3 powder containing about 30 ppm Si and Al was analyzed directly by slurry injection while relatively impure Fe 2 O 3 was dissolved by high-pressur...

我们正在为您处理中,这可能需要一些时间,请稍等。

资源合作:cnki.scholar@cnki.net, +86-10-82896619   意见反馈:scholar@cnki.net

×