全部文献期刊会议图书|学者科研项目
中外文文献  中文文献  外文文献
作者:Ping Cheng , Gregory K. Koyanagi , Diethard K. Bohme
来源:[J].Analytica Chimica Acta(IF 4.387), 2008, Vol.627 (1), pp.148-153
摘要:... Among these four molecules, SF 6 exhibits the largest difference in reactivity, almost a factor of 10 4 , and so is identified as the kinetically recommended reagent for the chemical resolution of the isobaric interference of 87 Rb + and 87 Sr + .
作者:Xuhai Be , Earl S. Moore , Zhiyang Zhao ...
来源:[J].Journal of Pharmaceutical and Biomedical Analysis(IF 2.947), 2013, Vol.74, pp.171-177
摘要:... A co-eluting, isobaric interference was discovered in preliminary LC–MS/MS analyses of rodent in vivo pharmacokinetic samples during preclinical evaluation of AMG 900. The interference was identified as a major circulating N-oxide metabolite which partially converted t...
作者:Jong-Sik Ryu , Min Seok Choi , Youn-Joong Jeong ...
来源:[J].Journal of Analytical Science and Technology, 2013, Vol.4 (1), pp.1-5
摘要:... Here, we present multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) Sm-Nd isotopic results for a series of mixed standard solutions with different Sm/Nd ratios to test the validity of isobaric interference corrections of Nd isotopic composition and exter...
作者:Min Seok Choi , Chang-Sik Cheong , Jeongmin Kim ...
来源:[J].Journal of Analytical Science and Technology, 2013, Vol.4 (1), pp.1-7
摘要:Abstract(#br) Background(#br)The Lu-Hf isotope system is widely used to decipher the crustal evolution and mantle differentiation of the Earth. The most critical point in obtaining accurate Hf isotope data is to correct the isobaric interferences of Yb and Lu imposed on the 176 H...
作者:Chi-Gyu Lee , Jinkyu Park , Sang Ho Lim
来源:[J].Nuclear Engineering and Technology(IF 0.576), 2018, Vol.50 (1), pp.140-144
摘要:... The isotope ratios for plutonium in the individual mixed particles, including 238 Pu/ 239 Pu, 241 Pu/ 239 Pu as well as 240 Pu/ 239 Pu, and 242 Pu/ 239 Pu, were in good agreement with the certified values despite the isobaric interference of 238 U and 241 Am. The isotope r...
作者:Mathieu Lahaie , Nikolay Youhnovski , Milton Furtado ...
来源:[J].Rapid Communications in Mass Spectrometry(IF 2.509), 2014, Vol.28 (8), pp.886-892
摘要:RATIONALE(#br)Liquid chromatography/tandem mass spectrometry (LC/MS/MS) instruments are selective and sensitive but can still be affected by isobaric interference or chemical noise arising from multiple sources such as the mobile phase. In this study, a high‐performance liquid...
作者:Chi-Gyu Lee, Ph.D. , Jinkyu Park, Ph.D. , Sang Ho Lim, Ph.D.
来源:[J].Nuclear Engineering and Technology(IF 0.576), 2018, Vol.50 (1), pp.140-144
摘要:... The isotope ratios for plutonium in the individual mixed particles, including 238Pu/239Pu, 241Pu/239Pu as well as 240Pu/239Pu, and 242Pu/239Pu, were in good agreement with the certified values despite the isobaric interference of 238U and 241Am. The isotope ratios for ur...
作者:Suresh K. Aggarwal , Sanjai Kumar , Manoj K. Saxena ...
来源:[J].International Journal of Mass Spectrometry and Ion Processes, 1995, Vol.151 (2), pp.127-135
摘要:Abstract(#br)Three different methodologies are reported for circumventing the isobaric interference of 238 Pu at 238 U during simultaneous thermal ionization mass spectrometric analysis of U and Pu. These are as follows: (i) obtaining the 235 U 238 U amount ratio at lower evapor...
作者:Ming Guan , Dongsheng Dai , Lin Li ...
来源:[J].Talanta(IF 3.498), 2017, Vol.172, pp.206-214
摘要:... The isomer TGs interference, the isobaric interference, and oxidized TG species interference were firstly indicated. Several isomer TGs, for example, 18:1/20:1/18:2 TG and 20:3/18:1/18:0 TG, which were all 56:4 TG, demonstrated different trends in HCC tissue compared with par...
作者:Ng Eddy Wing Yin , Lam Hugh Simon , Ng Pak Cheung ...
来源:[J].Mass spectrometry (Tokyo, Japan), 2014, Vol.3 (Spec Issue), pp.S0030
摘要:... It is well known that isobaric interference substances can be occasionally present in complex biological samples, and affect the accuracy of measurement by SRM. Unfortunately, by design it is not possible to assess whether isobaric interference happens in a SRM analysis. In c...

我们正在为您处理中,这可能需要一些时间,请稍等。

资源合作:cnki.scholar@cnki.net, +86-10-82896619   意见反馈:scholar@cnki.net

×